Chapter 3 Operating Principles | PCI-DMC-A01 / PCI-DMC-B01
Revised March, 2012 3-103
4) Select AD Conversion Time mode:
Figure 3.138
Conversion Time item: Select Conversion Time mode.
5) Select AD Channel / Display mode / Average data.
Figure 3.139
Channel item: Select Channel for AD enable input.
Mode item: Select AD display range.
Average item: Select wave display calculation frequency.
Data item: Enter AD voltage or current display position.
6) AD reset and maximum:
Figure 3.140
Zero item: Click this button to carry out re-zero (e.g. selectDA Mode -5~5, set lever
to 0 position then click on Zero button to complete zeroing operation)
Full item: Click this button to set maximum (e.g. select DA Mode -10~10, set lever
to 10 then click on Full button to complete the set maximum operation)