Warning
Please read this instruction carefully before use.
Switch off the power before wiring.
The display panel of TP02 series is waterproof. But please prevent grease, corrosive liquids and sharp objects from
contacting the TP02 series.
The TP02 series require 24V DC input power. DO NOT connect input AC power supply to any of the RS-485
communication port; otherwise serious damage may occur. Check all the wiring again before switching on the
power.
DO NOT touch any terminal when the power is switched on. DO NOT touch any internal circuit in 1 minute after
the power is switched off.
Make sure the groud terminal is correctly grounded in order to prevent electromagnetic interference.
Please use the fixed support accessory which is packed together with the product provided by Delta. DO NOT
tighten the screws out of the normal torque specifications; otherwise serious damage may occur.
Introduction
Product Outline
Display ing Area
Escape / Exit Key
Alarm LED Indic ator
Function Keys
Arrow Keys
Enter Key
Panel Function Explanation
Panel component
Explanation
Alarm LED
indicator (RED)
Status 1: When power is on, LED will blink slowly for three times.
Status 2: When there is an abnormal situation, LED will blink quickly along with an alarm sound.
RS-232 LED
indicator (yellow)
LED will blink when transmits program and communicates via RS-232.
RS-485 LED
indicator (green)
LED will blink when communicates via RS-485.
Displaying area Liquid Crystal Module display area. It is used to display current program status.
Escape/Exit key It is used to cancel an incorrect input, or to exit a programming step.
Enter key It is used to input a value or accept a programming command.
Arrow keys
UP/Pg Up: It is used to increase the value or move up one page.
Pg Dn/DOWN: It is used to decrease the value or move down one page.
Left: This key is left direction key and it can be used to select the position of the value.
Right: This key is right direction key and it can be used to select the position of the value.
Function keys
F0/0: It is used as a constant 0, or the user can define it as function F0.
F1/1: It is used as a constant 1, or the user can define it as function F1.
F2/2: It is used as a constant 2, or the user can define it as function F2.
F3/3: It is used as a constant 3, or the user can define it as function F3.
F4/4: It is used as a constant 4, or the user can define it as function F4.
F5/5: It is used as a constant 5, or the user can define it as function F5.
F6/6: It is used as a constant 6, or the user can define it as function F6.
F7/7: It is used as a constant 7, or the user can define it as function F7.
F8/8: It is used as a constant 8, or the user can define it as function F8.
F9/9: It is used as a constant 9, or the user can define it as function F9.
ENGLISH
Back Panel
RS-232
5 PIN terminal/Wire gauge: 12-24 AWG/Torque: 4.5 lb.-inch
Dimension
Front panel (unit: mm [inch]) Right side diagram (unit: mm [inch])
Vertical view (unit: mm) Mounting dimension (unit: mm [inch])
Thickness Range 0.5~9mm
135~136.5[5.31~5.37]
85
[3.35]
Installation
Please insert TP02 series to the opening hole of panel and tighten the screws. However, if a firm mounting
TP02 series to the panel is needed, please use the mounting fixed support accessory which is packed together
with TP02 series, then insert the fixed support in the back and tighten the screws.
If the fixed support is not installed well, Delta will not guarantee the waterproof function. The screw torque
should be 4-5(kg-cm). DO NOT exceed this specification when tightening the screws; otherwise TP02 series
may be damaged. Please leave sufficient space (more than 50mm) around the unit for heat dissipation.
Notes: The flat surface should be a UL Type 4 "Indoor Use Only" enclosure or equivalent (IP65/NEMA4). Please refer to
the figures below.
Specifications
Function Specifications
Item TP02G-AS1
Screen type STN-LCD
Display color Monochromatic
Backlight
The back-light automatic turn off time is 1 ~ 99 minutes (0 = DO NOT turn off)
(The back-light life is about 50 thousand hours at 25°C)
Resolution 160 x 32 dots
5×8 dots, 25 characters×8 rows
8×8 dots, 16 characters×8 rows
8×12 dots, 16 characters×5 rows
8×16 dots, 16 characters×4 rows
Display range (W) x (H) = 72 x 22 (unit: mm)
Contrast adjustment
15 levels of adjustment
Language/font
ASCII: Alphanumeric (including European characters)
Taiwan: (Big 5 codes) Traditional Chinese Fonts
China: (GB2324-80 codes) Simplified Chinese Fonts
Font size ASCII: 5 × 8, 8 × 8, 8 × 12, 8 × 16
Alarm LED indicator
(RED)
1. Power on indication (blink for three times)
2. Communication error alarm
3. Special indication by user programming
RS-232 LED
indicator (yellow)
It will blink when transmitting program and communicating by using RS-232.
Display
screen
RS-485 LED
Indicator (green)
It will blink when communicating by using RS-485.
Program memory 256KB flash memory
RAM of system 32K Byte
Serial
communication port
RS-232 (COM1)
Unsynchronized transmission method: RS-232
Data length: 7 or 8 bits, Stop bits: 1 or 2 bits
Parity: none/odd/even, Transmission speed: 4,800 bps ~115,200 bps
RS-232: 9 PIN D-SUB male
Extension
communication port
RS-485 (COM2)
Unsynchronized transmission method: RS-485
Data length: 7 or 8 bits, Stop bits: 1 or 2 bits
Parity: None/Odd/Even, Transmission speed: 4,800 bps ~115,200 bps
RS-485: 5 PIN removal terminal
Extension interface 1. Update firmware version
2. The slot for program copy card
External
interface
5 PIN removal
terminal
Include 24V DC input and RS-485 communication input
Electrical Specifications
Specifications TP02G-AS1
Communication interface COM1: RS-232 COM2: RS-485
Waterproof class of front panel IP65/NEMA4
Operating temperature for
hardware
0 ~ 50°C; 20 ~ 90%RH (non-condensing)
Specifications TP02G-AS1
Storage temperature for
hardware
-20 ~ 60°C
Vibration
5Hz f 9Hz = Continuous: 1.75mm / Occasional: 3.5mm
9Hz f 150Hz = Continuous: 0.5g / Occasional: 1.0g
Shock
15g peak, 11ms duration, half-sine, three shocks in each direction per axis,
on 3 mutually perpendicular axes (total of 18 shocks)
Radiated emission CISPR11, Class A
Electrostatic discharge immunity
EN61000-4-2
Radiated immunity EN61000-4-3
Electrical fast transient EN61000-4-4
Weight/dimensions 0.24kg; 147 × 97 × 35.5mm (Width(W) × Height(H) × Deep(D))
Cooling method Natural air cooling
Password Function
1. If the user forgot the password, the password can be cleared by using the following code: 8888. This
universal code will clear the password and all TP02 series internal programs. The TP02 series will be reset to
the factory settings by using this code also. Please pay close attention when using it.
2. The password can be the alphabet from A to Z or the number from 0 to 9. But it must use the function keys F0
~ F9 to input the password characters. Please refer to the following table.
F0: scrolls in a loop as follows 0→A→B→C→D→E→F→0.
F1: scrolls in a loop as follows 1→G→H→I→J→K→1.
F2: scrolls in a loop as follows 2→L→M→N→O→P→2.
F3: scrolls in a loop as follows 3→Q→R→S→T→U→ V→3.
F4: scrolls in a loop as follows 4→W→X→Y→Z→4.
F5: It just can be used to be constant 5.
F6: It just can be used to be constant 6.
F7: It just can be used to be constant 7.
F8: It just can be used to be constant 8.
F9: It just can be used to be constant 9.
Hardware Operation
When the user wants to startup TP02 series, a 24V DC power is needed. After applying 24V DC power to TP02
series, it will enter into the startup display and then enter the user-designed program. Pressing Esc key and
holding on for 5 seconds can return to system menu. There are five selections in the system menu and are
described below.
Selections Explanation
Download
program
Use the connection cable (DVPACAB530) to connect the TP02 serial communication port RS-232 to a
PC. Then use the TPEditor software to download an application program to TP02.
Upload program
Use the connection cable (DVPACAB530) to connect the TP02 serial communication port RS-232 to a
PC. Then use the TPEditor software to upload an application program from TP02.
Copy program
Transfer a program between two TP02 units.
1: transmit programs; 2: receive programs.
When transmit programs and data between two TP02 units. Set one TP02 to “Receive Program”
mode and the other TP02 to “Transmit Program” mode. Please use twisted pair wires to connect the
two units via the RS-485 ports.
Selections Explanation
TP02 settings
There are 8 items that used to modify TP02 system settings:
1. Communication protocol: Setting the address of TP02, the control port of PLC, and the
communication string for either RS-232 or RS-485.
2. Contrast: Adjust the contrast of LCM display screen.
3. Back-light: adjust the automatic turn off time of LCM. Setting range is 00 ~ 99 minutes. If set to 00,
the LCM Back-light will not turn off.
4. Buzzer: Used to set the buzzer sound, normal mode or quiet mode.
5. Language setting: Used to set the displayed language. English, Traditional Chinese, Simplified
Chinese or user defined language.
6. Password setting: Used to set, enable, and disable the password function. If the password function
is enabled, it will require the user to input a password before entering any system menu. The
factory password is 1234.
7. Startup display: Used to select the TP02 startup display. User can select “user defined” to use the
file that designed by TPEditor and download to TP02.
8. Comm. indicator: The user can determine if the RS-232 and RS-485 LEDs will blink or not during
communication.
PLC connection
There are two methods to connect to PLC:
1. Using TP02 serial communication port (COM1) RS-232: set 8-pin DIP switch to RS-485 mode and
connect the cable (DVPACAB215 or DVPACAB230) to program communication I/O RS-232C of
PLC.
2. Using extension communication port (COM2) RS-485: set 8-pin DIP switch to RS-485 mode and
connect 5-pin removal terminal of extension communication port to RS-485 of PLC with twisted
pair.
Execution
Execute the internal program that download from TPEditor or transmitted from other TP02 units.
When program is in execution, the user can return to system menu by pressing Escape/Exit (Esc) key
for 5 seconds.
Communication Connection
TP02G may connect to a PC by using connection able DVPACAB515
1
5
6
9
TO PC (R S- 2 32)
TO TP02 / 04G
9 PIN D- S UB fem ale
Rx 2
GND 5
5 GND
PC COM Port
9 PIN D- S UB fem ale
3 Tx
2 Rx
TP 02 / 04G C O M Port
Tx 3
TP02G may connect to a DVP-PLC by using connection cable DVPACAB215/DVPACAB230/
DVPACAB2A30
DVPACAB215/DVPACAB230
1
13
14
1
5
6
9
25 P I N D-S U B
9 P IN D- SU B
TO P LC
M I N I D I N TERM I N AL
DVPACAB2A30
1
5
6
9
TO PLC
MIN I DIN TER MINAL
PC / TP C O M Port PLC C O M1 P ort
Tx
2
GN D 7
8 PIN MIN I DIN9 P I N D -SUB f e m a l e
PC / TP C OM Port
PLC C O M1 P ort
R x 2
GN D 5
6
8
20
4
5
1
4
6
7
8
x
8 G ND
1,2 5V
1
2
3
5
6
7
8
5 Tx
Rx 3
Tx 3
1
2
3
4
5
7
x
1,2 5V
5 T x
24V RS-485
LC M
RS-23 2
/
RS-48 5
RS-232
RS-232
RS-485 RS-485
/
UP/Pg Up
Pg Dn/DOWN
Left
Right
F0/0 0 F0
F1/1 1 F1
F2/2 2 F2
F3/3 3 F3
F4/4 4 F4
F5/5 5 F5
F6/6 6 F6
F7/7 7 F7
F8/8 8 F8
F9/9 9 F9
RS-232
5-Pin / 12-24 AWG / 4.5 lb-inch
( mm)
97.00 [3.82]
147.00 [5. 79]
( mm)
30.50 [1.20]
( mm) ( mm)
4-5 (kg-cm)
Type 4