Chapter 3 Creating and Editing Programs|DOP-EXIO Series
3-18
Revision March, 2008, Doc. Name: 2007PDD23000014
Activate “Search/Replace” fuction to open “Search/Replace” dialog box and choose the
“Search Device” tab. Enter device name “Y0” in the field of “Search Device” and select
the “None” in the field of “Type”. Then, press the “Search” button and the system will
find the instructions “OUT Y0” and “INC K4Y0”.
However, if enter the device name “Y0” in the field of “Search Device” still, but change
the “None” to “Fun.” in the field of “Type”, only the instruction “INC K4Y0” will be found
when “Search” button is pressed.
Replace Device
Use this command to replace the specified device name match the search criteria in the
program. For example, activate “Search/Replace” fuction and choose the “Replace
Device” tab. In “Replace Device” tab, enter the “X0” in the field of “Search Device” and
select the type of search device as “LD”. Then, enter the “M100” in the field of “Replace
Device” and select the type of replace device as “LD”. Next, type in “10” in the field of
“Device Number”. Finally, press the “Replace” button, and the instructions which match
the criteria will be changed to LD M100~M109.