Delta Electronics LCP-2125 Manual de usuario Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
Deluxe LCP-1250xxxDM Series
DELTA ELECTRONICS, INC.
18 2004/10
Rev. 0A
www.deltaww.com
Status Bits (2 Wire Address A2h)
Address Bit Name Description
110 7 TX Disable State Not implement.
110 6 Soft TX Disable Not implement.
110 5 Reserved
110 4 RX Rate Select State Not implement.
110 3 Soft RX Rate Select Not implement.
110 2 TX Fault
Digital state of the TX Fault Output Pin. Updated within 100msec of
change on pin.
110 1 LOS
Digital state of the LOS Output Pin. Updated within 100msec of
change on pin.
110 0 Data_Ready_Bar
Indicates transceiver has achieved power up and data is ready. Bit
remains high until data is ready to be read at which time the device
sets the bit low.
Alarm and Warning Flag Bits (2 Wire Address A2h)
Address Bit Name Description
112 7 Temp High Alarm Set when internal temperature exceeds high alarm level.
112 6 Temp Low Alarm Set when internal temperature is below low alarm level.
112 5 Vcc High Alarm Set when internal supply voltage exceeds high alarm level.
112 4 Vcc Low Alarm Set when internal supply voltage is below low alarm level.
112 3 TX Bias High Alarm Set when TX Bias current exceeds high alarm level.
112 2 TX Bias Low Alarm Set when TX Bias current is below low alarm level.
112 1 TX Power High Alarm Set when TX output power exceeds high alarm level.
112 0 TX Power Low Alarm Set when TX output power is below low alarm level.
113 7 RX Power High Alarm Set when Received Power exceeds high alarm level.
113 6 RX Power Low Alarm Set when Received Power is below low alarm level.
113 5-0 Reserved Alarm
114 All Reserved
115 All Reserved
116 7 Temp High Warning Set when internal temperature exceeds high warning level.
116 6 Temp Low Warning Set when internal temperature is below low warning level.
116 5 Vcc High Warning Set when internal supply voltage exceeds high warning level.
116 4 Vcc Low Warning Set when internal supply voltage is below low warning level.
116 3 TX Bias High Warning Set when TX Bias current exceeds high warning level.
116 2 TX Bias Low Warning Set when TX Bias current is below low warning level.
116 1 TX Power High Warning Set when TX output power exceeds high warning level.
116 0 TX Power Low Warning Set when TX output power is below low warning level.
117 7 RX Power High Warning Set when Received Power exceeds high warning level.
117 6 RX Power Low Warning Set when Received Power is below low warning level.
117 5-0 Reserved Warning
118 All Reserved