Digital Diagnostic Monitoring Interface
Alarm and Warning Thresholds (2-Wire Address A2h)
Address
#
Bytes
Name Value (Dec.) Unit Note
00-01 2 Temp High Alarm 78
02-03 2 Temp Low Alarm -13
04-05 2 Temp High Warning 73
06-07 2 Temp Low Warning -8
08-09 2 Voltage High Alarm 3.8
10-11 2 Voltage Low Alarm 2.8
12-13 2 Voltage High Warning 3.6
14-15 2 Voltage Low Warning 3.0
Volt
16-17 2 Bias High Alarm I
OP
*2+35
18-19 2 Bias Low Alarm I
OP
-13
20-21 2 Bias High Warning I
OP
*2+30
22-23 2 Bias Low Warning I
OP
–8
mA 1
24-25 2 TX Power High Alarm 7
26-27 2 TX Power Low Alarm -2
28-29 2 TX Power High Warning 6
30-31 2 TX Power Low Warning -1
dBm
32-33 2 RX Power High Alarm -8
34-35 2 RX Power Low Alarm -30
36-37 2 RX Power High Warning -9
38-39 2 RX Power Low Warning -29
dBm
40-45 16 Reversed
56-91 36 External Calibration Constants
92-94 3 Reversed
95 1 Checksum 2
96-97 2 Real Time Temperature
98-99 2 Real Time Supply Voltage
100-101 2 Real Time Tx Bias Current
102-103 2 Real Time Tx Optical Power
104-105 2 Real Time Rx Received Power
106-109 4 Reserved
110 1 Optional Status/ Control Bits
111 1 Reserved
112-119 8 Optional Set of Alarm and Warning
Notes:
1) I
OP
: Operating current at room temperature. The min. setting current is 0 mA.
2) Byte 95 contains the low order 8bits of sum of bytes 0-94.