SFP timing parameters for SFP management
Parameter
Symbol
Min.
Max.
Unit
Note
TX_DISABLE Assert time t_off 100 msec 1
TX_DISABLE Deassert time t_on 100 msec 2
Time to initialize, including
reset of TX_FAULT
t_init 300 msec 3
TX Fault Assert Time
t_fault
100 msec 4
LOS Assert Time t_loss_on 100 msec 5
LOS Deassert Time t_loss_off 100 msec 6
Serial ID Clock Rate f_serial_clock 100 kHz
Notes:
1)
Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal
2)
Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90% of
nominal
3)
From power on or negation of TX_Fault using TX Disable
4)
Time from fault to TX fault on.
5) Time from LOS state to Rx LOS assert
6) Time from non-LOS state to Rx LOS deassert