Chapter 5 Description of Parameter Settings
© 1999 DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
25
& Display states:
d 0: no password / correct password has been input.
d 1: parameters are locked.
0 - 08 Password Configuration Factory Setting: d 0
Settings d 0 to d 999 Unit: 1
& For a password to be configured, the non-zero value assigned to Pr.0-08 must
be entered twice. In other words, set the value of Pr.0-08 to the desired
value and press the Prog/Data key. Then, press the Prog/Data key again to
display the value of Pr.0-08. Finally, press the Prog/Data key again to store
the displayed value, which then becomes the password.
For example, say that pr.0-08 is set to 111. When the AC drive is powered-
up, all the parameters will be locked and their values cannot be changed. To
permit the values of parameters to be altered, navigate to Pr.0-07 and change
its value to 111 (the password configured in Pr.0-08). Then press the
Prog/Data key, and you may alter the parameter values.
& Display states:
d 0: no password
d 1: password has been set