Chapter 13 Recipe Access Example
Revision March, 2014 13-17
Press icon. The following dialog box will pop-up and ask the users to enter the
password.
Please enter 12345678 in the filed of the password at the first time (12345678 is the
default setting value and the users can change it freely). After the correct password is
entered, the
icon will display on the tool bar at the left-bottom corner.
When eServer performs reading, due to enable auto refresh on startup, it will auto import
recipe to destination path, but if disable enable auto refresh on startup, please trigger the
character input element on HMI and enter TINA these four characters, then wait for 5
second to import recipe to destination path. Please refer to the figure below: