Delta-electronics Programmable Logic Controller DVP-PLC Manual de usuario Pagina 315

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 586
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 314
7 Application Instructions API 50-99
DVP-PLC APPLICATION MANUAL
7-31
Program Example 1:
M1000
DPLSY K1000 K1000
EI
FEND
Y0
I 001
IRET
SET M1347
M1000
DPLSY K1000 K1000 Y2
I 101
IRET
SET M1348
END
Explanations:
a) Whenever X0 is triggered, Y0 will output 1,000 pulses; whenever X1 is triggered, Y2 will output 1,000 pulses.
b) When X triggers Y pulse output, there should be an interval of at least one scan time between the end of Y
pulse output and the next X-triggered output.
Program Example 2:
X1
M1347
PLSY K1000 K1000 Y0
X2
END
Explanations:
When both X1 and X2 are On, Y0 pulse output will keep operating. However, there will be a short pause (approx.
1 scan time) every 1,000 pulses before the output of the next 1,000 pulses.
Vista de pagina 314
1 2 ... 310 311 312 313 314 315 316 317 318 319 320 ... 585 586

Comentarios a estos manuales

Sin comentarios