Delta-electronics Programmable Logic Controller DVP-PLC Manual de usuario Pagina 331

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 586
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 330
7 Application Instructions API 50-99
DVP-PLC APPLICATION MANUAL
7-47
Lower bound value Upper bound value Present value in C10 Output
D104 = 140 D105 = 170
140 C10 170
M12 = On
D106 = 150 D107 = 390
150 C10 390
M13 = On
5. If the lower bound value > upper bound value, when C10 < upper bound value (60) or > upper bound value (140),
M12 will be On.
Lower bound value Upper bound value Present value in C10 Output
D100 = 40 D101 = 100
40 C10 100
M10 = On
D102 = 120 D103 = 210
120 C10 210
M11 = On
D104 = 140 D105 = 60
60 C10 140
M12 = On
D106 = 150 D107 = 390
150 C10 390
M13 = On
4002000
40
100
120 210
60
140
150 390
M10
M11
M12
M13
Vista de pagina 330
1 2 ... 326 327 328 329 330 331 332 333 334 335 336 ... 585 586

Comentarios a estos manuales

Sin comentarios