Delta Electronics AC Servo Drive ASDA-AB Manual de usuario Pagina 107

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 305
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 106
Chapter 6 Control Modes of Operation ASDA-A User Manual
4th Edition 2005/11/30, HE03 © DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
6-10
6-2-6 Low-pass Filter
Relevant parameters:
P1 - 08 PFLT
Smooth Constant of Position Command (Low-pass
filter)
Communication Addr.: 0108H
Default: 0 Applicable Control Mode: P
Range: 0~1000 (0: Disabled)
Unit: 10 msec
PFLT
Target position
6-2-7 Timing Chart of Position (Pr) Control Mode
In Pr mode, position command source is DI signal from CN1, i.e. selected by POS0~POS2 and CTRG.
Please refer to 6-2-2 to see the relationship between DI signals and parameters. The following figure is
shown the timing chart of Pr mode:
P8
P3
P2
P1
POS0
POS1
CTRG
SON
External I/O signal
OFF
ON
OFF
ON
ON
OFF
ON
>2ms, can be set by P2-09
POS2
ON
OFF
Internal position
command
1ms
Vista de pagina 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 304 305

Comentarios a estos manuales

Sin comentarios