Chapter 5 Trial Run and Tuning Procedure ASDA-A User Manual
4th Edition 2005/11/30, HE03 © DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
5-6
Overcurrent:
Corrective Actions:
 Check the wiring connections between drive and motor.
 Check if the circuit of wire is closed.
 Repair the short-circuited and avoid metal conductor being exposed.
7) When display shows:
Undervoltage:
Corrective Actions:
 Check whether the wiring of main circuit input voltage is normal.
 Use voltmeter to check whether input voltage of main circuit is normal.
 Use voltmeter to check whether the input voltage is within the specified specification.
Note: If there are any unknown fault codes and abnormal display when applying power to the drive or
servo on is activated (without giving any command), please inform the distributor for assistance.