Chapter 7 Parameters ASDA-A User Manual
4th Edition 2005/11/30, HE03 © DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
7-22
P0 - 04 CM1
Status Monitor 1 Communication Addr.: 0004H
Default: 0 Applicable Control Mode: P/S/T
Range: 0~16
Select the desired drive status through the keypad or communication setting (please refer to
P0-02). The drive status can be read from the communication address of this parameter via
communication port.
P0 - 05 CM2
Status Monitor 2 Communication Addr.: 0005H
Default: 0 Applicable Control Mode: P/S/T
Range: 0~16
See P0-04 for explanation.
P0 - 06 CM3
Status Monitor 3 Communication Addr.: 0006H
Default: 0 Applicable Control Mode: P/S/T
Range: 0~16
See P0-04 for explanation.
P0 - 07 CM4
Status Monitor 4 Communication Addr.: 0007H
Default: 0 Applicable Control Mode: P/S/T
Range: 0~17
If users set this parameter to 17, the status of DI signal can be read.
See P0-04 for explanation.
P0 - 08 CM5
Status Monitor 5 Communication Addr.: 0008H
Default: 0 Applicable Control Mode: P/S/T
Range: 0~17
If users set this parameter to 17, the status of DO signal can be read.
See P0-04 for explanation.
P0 - 09 MAP0
Block Data Read/Write Register 0 Communication Addr.: 0009H
Default: 407H Applicable Control Mode: P/S/T
Range: 100H~417H
Set the register address in HEX that users want to read and write by using the keypad.
Users can enter the desired register address (0100H~0417H) into P0-09 to P0-16 (0009H~
0010H). Then, users can read and write up to 8 continuous specified block data from the
communication address 0009H to 0010H through the communication port.