Chapter 7 Servo Parameters|ASDA-B Series
Revision January, 2009 7-37
P1 - 46
GR3 Encoder Output Pulse Number Communication Addr.: 012EH
Default: 2500 Related Section:
Applicable Control Mode: P/S/T P1-03
Unit: pulse
Range: 1 ~ 2500 (0 = By pass)
Settings:
This parameter is used to set the pulse number of encoder outputs.
Encoder output pulse number (A/B phase deviation from 90 degrees (Quadrature))
=
2500ppr
2500
x setting value of P1-46
P1 - 47
Reserved Communication Addr.: 012FH
P1 - 48
Reserved Communication Addr.: 0130H
P1 - 49
Reserved Communication Addr.: 0131H
P1 - 50
Reserved Communication Addr.: 0132H
P1 - 51
Reserved Communication Addr.: 0133H
P1 - 52
RES1 Regenerative Resistor Value Communication Addr.: 0134H
Default: 40 Related Section:
Applicable Control Mode: P/S/T Section 6.6.3
Unit: Ohm
Range: 10 ~ 750
P1 - 53
RES2 Regenerative Resistor Capacity Communication Addr.: 0135H
Default: 60 Related Section:
Applicable Control Mode: P/S/T Section 6.6.3
Unit: Watt
Range: 30 ~ 1000