1 TPEditor Operation
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
1-67
Figure 1-119
Step 2. Then, Page Jump Condition Setting tab will display on the screen. The users can select the Refer
Device as Bit (Figure 1-120) or Value (Figure 1-121) device in Condition Setting option. Max. 20 pages
could be set.
Figure 1-120 Figure 1-121
Step 3. After entering the device name and clicking
, the Refer Device tab will open (Figure1-122). In the
Refer Device tab, the users can enter device name, set device number and communication address.
The device name could be X, Y, M, S, D, C, and T and the device number is indicated in decimal
format. When entering into the Refer Device tab, the users should select the desired device type (Bit or
Value) first. If the Refer Device is set to Bit, the available device could be X, Y, M, S, C, T. If the Refer
Device is set to Value, the available device could be T, C, D. The users could click
to select the
necessary Device Name. If the connected controller is AC motor drive (Inverter), it does not need to
check the Device Name. The symbol $ will show after the Device Name to represent the absolute
address of AC motor drive. What the users need to do is to input absolute address in the field of Device
Number. For example, if the register is D10, the communication address is used to determine which