11
Parameters Functions Settings
Factory
Setting
6-04
Over-torque
detection time
0.1 ~ 10.0 Sec 0.1
6-05
Electronic thermal
overload relay
0: Not used
1: Act with standard motor
2: Act with special motor
0
6-06
Electronic thermal
characteristic
30~600 Sec 60
6-07 Present fault record
6-08
Second most recent
fault record
6-09
Third most recent
fault record
6-10
Forth most recent
fault record
6-11
Fifth most recent
fault record
6-12
Sixth most recent
fault record
0: No fault occurred
1: oc (over current)
2: ov (over voltage)
3: oH (over heat)
4: oL (over load)
5: oL1 (electronic thermal)
6: EF (external fault)
7: Reserved
8: Reserved
9: ocA (current exceed during acceleration)
10: ocd (current exceed during deceleration)
11: ocn (current exceed during steady state)
0
Group 7: Motor Parameters
Parameters Functions Settings
Factory
Setting
a
7-00 Motor rated current 30~120 % 85
a
7-01 Motor no-load current 0 ~ 90 % 50
a
7-02
Torque
compensation
0 ~ 10 1
a
7-03 Slip compensation 0.0 ~ 10.0 0.0
Group 8: Special Parameters
Parameters Functions Settings
Factory
Setting
8-00 DC braking voltage level 0 ~ 30% 0
8-01
DC braking time during
start-up
0.0 ~ 60.0 Sec 0.0
8-02
DC braking time during
stopping
0.0 ~ 60.0 Sec 0.0
8-03 Start-point for DC braking 0.0 ~ 400.0 Sec 0.0
8-04 Momentary power loss 0: Stop operation after momentary power
loss.
1: Continues after momentary power loss,
speed search starts with master freq.
2: Continues after momentary power loss,
speed search starts with min. output
freq.
0