DVPEN01-SL Ethernet Communication Module Operation Manual DVP-0204320-03
Ethernet Communication Module DVPEN01-SL 4.2 Explanations on CR CR#0: Model code Explanations: 1. Model code of DVPEN01-SL=H’4050. 2. You can read
Ethernet Communication Module DVPEN01-SL Data Exchange CR#13: Data exchange trigger Explanations: CR#13 Execution 0 The data in data exchange ar
Ethernet Communication Module DVPEN01-SL CR#27: Function code for a data exchange mode Explanations: 0: Using the function code “0x17” for the reading
Ethernet Communication Module DVPEN01-SL CR#85: Written-in address for data exchange Explanations: The number of transmission registers (K1~K100) in
Ethernet Communication Module DVPEN01-SL CR#94: Enabling the setting of an IP address Explanations: If the value in CR#94 is 1, the setting of an IP a
Ethernet Communication Module DVPEN01-SL CR value Data exchange status 0 The data have not been received. 1 The data exchange is in progress. 2 Th
Ethernet Communication Module DVPEN01-SL CR#16: Connection status of the RTU mapping slave Explanations: b3~b0 display the connection status of RTU sl
Ethernet Communication Module DVPEN01-SL 2. Select Ethernet as the transmission type. Broadcast search 1. Click Search in DCISoft to search for a
Ethernet Communication Module DVPEN01-SL 2. Click a model on the left hand side, and you will see the device list of the model selected on the right h
Ethernet Communication Module DVPEN01-SL Designating a model to search 1. Right click Ethernet on the left hand side window and click Configure t
Ethernet Communication Module DVPEN01-SL 3. List of the current DVPEN01-SL modules Searching by an IP address 1. Select Ethernet in the Communica
Ethernet Communication Module DVPEN01-SL 2. Click IP Search to start searching for the designated IP address. 3. The DVPEN01-SL module found will b
Ethernet Communication Module DVPEN01-SL Opening the DVPEN01-SL setup page by RS-232 1. Select RS232 as the transmission type in the Communication
Ethernet Communication Module DVPEN01-SL 5.2 Basic Settings The basic settings include parameters as module name, language, enabling MODBUS TCP and t
Ethernet Communication Module DVPEN01-SL as an offset from Greenwich Mean Time (see also UTC). Standard time zones can be defined by geometrically sub
Ethernet Communication Module DVPEN01-SL 3. Click on Internet Protocol (TCP/IP). 4. Enter 192.168.0.1 into the IP address box. Click on OK to compl
Ethernet Communication Module DVPEN01-SL 1. IP Configuration There are two types of IP address, static IP addresses and DHCP. Static IP address: Pres
Ethernet Communication Module DVPEN01-SL 5.4 Setting E-mails E-mail is the abbreviation of electronic mail, which transmits mails through the network
Ethernet Communication Module DVPEN01-SL allowed). 4. Selecting recipients: After you have set all the parameters for the E-mail, you will need to sel
Ethernet Communication Module DVPEN01-SL 5.6 Data Exchange DVPEN01-SL is able to designate a data exchange area for PLC MPUs to exchange and synchron
Ethernet Communication Module DVPEN01-SL Warning Please read this instruction carefully before use and follow this instruction to operate the devic
Ethernet Communication Module DVPEN01-SL 5.7 MELSEC Protocol DVPEN01-SL can communicate with Mitsubishi devices by means of the MELSEC protocol. It c
Ethernet Communication Module DVPEN01-SL Settoing the MELSEC protocol data exchange 1. Enable MELSEC Protocol Users can disable/enable the MELSEC
Ethernet Communication Module DVPEN01-SL 5. Please refer to section 6.15 for more information. 5.8 RTU Use the RTU function to conduct mapping betwee
Ethernet Communication Module DVPEN01-SL 5.9 IP Filter An IP filter is used for restricting the connection of the network in case some uncertain IP a
Ethernet Communication Module DVPEN01-SL 5.10 Static ARP Table ARP (Address Resolution Protocol) is used for obtaining the MAC address corresponding
Ethernet Communication Module DVPEN01-SL 5.11 Setting a Password To prevent the set values in DVPEN01-SL from being modified, you can set a password
Ethernet Communication Module DVPEN01-SL 5.12 Returning to Default Settings If you need to clear all the settings after many modifications on the set
Ethernet Communication Module DVPEN01-SL 2. Start WPLSoft, and click Ethernet in the Communication Setting Section. 3. Click Auto-Search Ethernet
Ethernet Communication Module DVPEN01-SL 5. After DELTA DVPEN01-SL in the Ethernet section is double-clicked, DCISoft will be started. Please refer to
Ethernet Communication Module DVPEN01-SL 6.2 Connecting the PC with DVPEN01-SL through LAN Application Setting the network parameters of DVPEN01-SL
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 2 5.9 IP Filter ...
Ethernet Communication Module DVPEN01-SL 4. All the devices connected to the network are shown in the Ethernet section. After DELTA DVPEN01-SL is clic
Ethernet Communication Module DVPEN01-SL 6. After the setting of an IP address is complete, and step 2~step 4 are repeated, the IP address can be used
Ethernet Communication Module DVPEN01-SL 3. Select the Modify checkbox, and enter “aabb” in the Password box and the Confirm Password box. Click on OK
Ethernet Communication Module DVPEN01-SL 5. Enter the password to temporarily unlock the protection and modify the parameters. If you close the setup
Ethernet Communication Module DVPEN01-SL 7. After the password is cleared, you can modify the parameters. 6.4 When the Password is Lost (Returning t
Ethernet Communication Module DVPEN01-SL 2. After the Factory Setting box is selected, a confirmation window will appear. Click on Yes to return to de
Ethernet Communication Module DVPEN01-SL 3. Select the Enable IP Filter checkbox. Enter “192.168.0.4” in the No. 1 IP Address box and “255.255.255.255
Ethernet Communication Module DVPEN01-SL 6.6 Setting a Static ARP Table Application Setting a static ARP table Network environment (1) MAC address
Ethernet Communication Module DVPEN01-SL 4. Enter “192.168.1.1” in No.2 IP Address box, and its MAC address is “00:18:23:10:00:04”. Click on OK to com
Ethernet Communication Module DVPEN01-SL 6.7 Application of E-mails Application Sending an E-mail to notify the administrator when the current statu
Ethernet Communication Module DVPEN01-SL 1 Introduction Thank you for choosing DVPEN01-SL module. To correctly install and operate DVPEN01-SL, please
Ethernet Communication Module DVPEN01-SL 4. After all the settings in DVPEN01-SL are completed, compile the ladder diagram in the MPU and download it
Ethernet Communication Module DVPEN01-SL 3. Select the Enable Data Exchange checkbox. Select Program Control in the Enable Confition drop-down list bo
Ethernet Communication Module DVPEN01-SL detect by the previous setting that No. 1 IP address is “192.168.0.4". Write the data in RTC into CR#
Ethernet Communication Module DVPEN01-SL 3. Select the Enable Data Exchange checkbox. Select Always Enable in the Enable Condition drop-down list box.
Ethernet Communication Module DVPEN01-SL 6.10 Application of Data Exchange (3) Firmware version 2.0 and above support this function. Application Enab
Ethernet Communication Module DVPEN01-SL 4. After all the settings in PLC_A are completed, you have to write a ladder diagram for the MPU and download
Ethernet Communication Module DVPEN01-SL Explanations: The data exchange will be executed every one second. Write “0” into CR#28, and PLC_B wil
Ethernet Communication Module DVPEN01-SL ENDSET M2M1RSTK100K1M2K14 D14RST M2RST M2= D14 K2= D14 K3FROMK100 K1TOPK100TOP K1 K1K0K14K13K100TOPK1K86
Ethernet Communication Module DVPEN01-SL 6.13 Application of MODBUS TCP Master Application Compiling MODBUS instruction by PLC_B, making Y0 of PLC_A
Ethernet Communication Module DVPEN01-SL K100K1TOPK100TOP K1 K1K0K100K1TOPK100TOPK1H0K6K125K119K116K115SET M2M1RSTMOV K0 D0= D0 K2INC D0ENDK100 K1M2
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 4 Item Specification Weight (g) 92 (g) 2 Product Profile & Outline 2.1 Dimen
Ethernet Communication Module DVPEN01-SL 6.14 RTU Mapping Application Using RTU mapping to read/write the remote digital I/O and analog I/O registers
Ethernet Communication Module DVPEN01-SL 3. Use DCISoft for DVPEN01-SL to set start addresses and numbers. (RX: M2000~M2009; RY: M3000~M3009; RCR (Rea
Ethernet Communication Module DVPEN01-SL 6.15 Application of the MELSEC Protocol Application Using Always Enable in the Enable Condition drop-down l
Ethernet Communication Module DVPEN01-SL 3 Installation & Wiring This section gives instructions on how to connect DVPEN01-SL with PLC MPU and ho
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 6 3.2 Connecting DVPEN01-SL to the Network: Connect DVPEN01-SL to the Ethernet Hub
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 7CR# HW LW Attribute Content Explanation #19 #18 R Error status of slaves in dat