1 TPEditor Operation
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
1-37
Step 9. After complete the settings, the users can get the screen like Figure 1-65 below.
Step 10. Click View(V) > Object Inspector command from the menu bar, a Property tab will show up on the
screen and display all the properties of the Numeric/ASCII Display object. The users also could
change the settings of the Numeric/ASCII Display object directly by using the drop-down lists in
Property tab.
Figure 1-65
■
Lamp(16x16)
There are two types of Lamp objects, Bit Lamp and Word Lamp for selections.
Bit Lamp: Choose Object(O) > Lamp(16x16)(L) > Bit Lamp(I) command from the menu bar or click the icon
on the toolbar to create a Bit Lamp object. After double-clicking the object, the following Bit
Lamp Setting tab will display (Figure 1-66). Then, the users can use this object to read the
corresponding PLC contacts (ON or OFF) or the value of PLC register, and display the read result or
value on the screen of TP series directly.
Figure 1-66