Delta Electronics AC Motor Drive VFD-VE Series Especificaciones Pagina 102

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 182
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 101
VFD-V Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
5-74
5.11 Group 10: Speed Feedback Parameter
10-00 PG (encoder) Pulses Factory setting 600
Settings 1~20000
This parameter sets the encoder pulse per revolution.
10-01 Encoder Input Setting (channel 1) Factory setting 0
Settings
Phase A leads in a forward run command and phase B leads in a
reverse run command. (rising/falling edge trigger) (Pulses x 4)
FWD REV
0
A
B
Phase B leads in a forward run command and phase A leads in a
reverse run command. (rising/falling edge trigger) (Pulses x 4)
FWD REV
1
A
B
Phase A is a pulse input and phase B is a direction input.
(low input = reverse direction, high input = forward direction)
FWD REV
2
A
B
Phase A is a pulse input and phase B is a direction input.
(low input = forward direction, high input = reverse direction)
FWD REV
3
A
B
Phase A is a forward run pulse, then phase B is High.
Phase B is a reverse run pulse, then phase A is High.
FWD REV
4
A
B
CALL NOW 800-985-6929
http://www.automatedpt.com
CALL NOW 800-985-6929
http://www.automatedpt.com
Vista de pagina 101
1 2 ... 97 98 99 100 101 102 103 104 105 106 107 ... 181 182

Comentarios a estos manuales

Sin comentarios