Delta Electronics AC Motor Drive VFD-VE Series Especificaciones Pagina 46

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 182
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 45
VFD-V Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
5-18
01-28 Skip Frequency 1 (upper limit) Factory setting 0.00
01-29 Skip Frequency 1 (lower limit)
Factory setting 0.00
01-30 Skip Frequency 2 (upper limit) Factory setting 0.00
01-31 Skip Frequency 2 (lower limit)
Factory setting 0.00
01-32 Skip Frequency 3 (upper limit) Factory setting 0.00
01-33 Skip Frequency 3 (lower limit)
Factory setting 0.00
Settings 0.00~400.00Hz
These parameters determine the skip frequencies of the AC drive.
Please use the following hierarchy when setting these parameters: Pr. 01-28 > Pr. 01-29 >
Pr. 01-30 > Pr. 01-31> Pr. 01-32 > Pr. 01-33. The Skip frequency will be disabled if this
rule is not followed.
The Skip Frequencies are useful when a motor has vibration at a specific frequency
bandwidth. By skipping this frequency, the vibration will be avoided.
CALL NOW 800-985-6929
http://www.automatedpt.com
CALL NOW 800-985-6929
http://www.automatedpt.com
Vista de pagina 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 181 182

Comentarios a estos manuales

Sin comentarios