3
VFD-M Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
3-3
3.2 External Wiring
Motor
Output AC
Line Reactor
Power Supply
Magnetic
contactor
Input AC
Line Reactor
EMI Filter
R/L1 S/L2
T/L3
U/T1 V/T2
W/T3
B1
B2
Braking
Resistor
Zero-phase
Reactor
Zero-phase
Reactor
FUSE/NFB
Items Explanations
Power
supply
Please follow the specific power
supply requirement shown in
APPENDIX A.
Fuse/NFB
(Optional)
There may be inrush current during
power up. Please check the chart of
APPENDIX B and select the correct
fuse with rated current. NFB is
optional.
Magnetic
contactor
(Optional)
Please do not use a Magnetic
contactor as the I/O switch of the AC
drive, this will reduce the operating
life cycle of the AC drive.
Input AC
Line
Reactor
(Optional)
Used to improve the input power
factor to reduce harmonics and
provide protection from AC line
disturbances. (Surge, switching
spike, power flick, etc.) AC line
reactor should be installed when the
power supply capacity is 500kVA or
more and exceeds 6 times of the
inverter capacity, or the wiring
distance exceeds 10m.
Zero-phase
Reactor
(Ferrite
Core
Common
Choke)
(Optional)
Zero phase reactors are used to
reduce radio noise especially when
audio equipment installed near the
inverter. Effective for noise reduction
on both the input and output sides.
Attenuation quality is good for a
wide range from AM band to 10Mhz.
Appendix B specifies zero phase
reactors. (RF220X00A)
EMI filter
(Optional)
To reduce electromagnetic
interference. Please refer to
Appendix B for detail.
Braking
Resistor
(Optional)
Used to reduce stopping time of the
motor. Please refer to the chart on
Appendix B for specific Braking
Resistors.
Output AC
Line
Reactor
(Optional)
Motor surge voltage amplitudes
depending on motor cable length.
For long motor cable applications
(>10m), it is necessary to install on
the inverter output side.