  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 97
VFD-M Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
8-2
Parameter
Explanation Settings
Factory
Setting
Customer
10.0
20.0
Pr.09
Minimum Output
Voltage
115V/230V: 0.1 to 255.0V
460V: 0.1 to 510.0V
575V: 0.1 to 637.0V
26.1
a
Pr.10
Acceleration Time 1 0.1 to 600.0 sec or 0.01 to 600.0 sec
10.0
a
Pr.11
Deceleration Time 1 0.1 to 600.0 sec or 0.01 to 600.0 sec
10.0
a
Pr.12
Acceleration Time 2 0.1 to 600.0 sec or 0.01 to 600.0 sec
10.0
a
Pr.13
Deceleration Time 2 0.1 to 600.0 sec or 0.01 to 600.0 sec
10.0
Pr.14
Accel S-curve 00 to 07
00
a
Pr.15
Jog Accel/Decel
Time
0.1 to 600.0 sec or 0.01 to 600.0 sec
1.0
a
Pr.16
Jog Frequency 0.00 to 400.0 Hz
6.00
a
Pr.17
1st Step Speed
Freq.
0.00 to 400.0Hz
0.00
a
Pr.18
2nd Step Speed
Freq.
0.00 to 400.0Hz
0.00
a
Pr.19
3rd Step Speed
Freq.
0.00 to 400.0Hz
0.00
a
Pr.20
4th Step Speed
Freq.
0.00 to 400.0Hz
0.00
a
Pr.21
5th Step Speed
Freq.
0.00 to 400.0Hz
0.00
a
Pr.22
6th Step Speed
Freq.
0.00 to 400.0Hz
0.00
a
Pr.23
7th Step Speed
Freq.
0.00 to 400.0Hz
0.00
Pr.24
Reserve Operation
Inhibition
00: Enable REV operation
01: Disable REV operation
00
Pr.25
Over-Voltage Stall
Prevention
00: Disable
115V/230V: 330 to 450 Vdc
460V: 660 to 900 Vdc
575V: 825 to 1025 Vdc
390
780
975
Pr.26
Over-current Stall
Prevention during
Acceleration
00: Disable
20% to 200%
150
Pr.27
Over-current Stall
Prevention during
Operation
00: Disable
20% to 200%
150
Pr.28
DC Braking Current
Level
00 to 100 %
00
Pr.29
DC Braking during
Start-u
p
0.0 to 5.0 sec
0.0
Pr.30
DC Braking during
Sto
pp
in
g
0.0 to 25.0 sec
0.0
Pr.31
Start-point for DC
Braking
0.00 to 60.00 Hz
0.00