Group 3 Output Function Parameters
Parameters Explanation Settings
Factory
Setting
3-00 Analog Output Signal
d0: analog frequency
d1: analog current
d0
3-01 Analog Output Gain
!
d1 to d200% d100
3-02 Desired Freq. Attained d1.0 to d400 Hz d1.0
3-03 Terminal Count Value d0 to d999 d0
3-04 Preliminary Count Value d0 to d999 d0
3-05
Multi-Function Output1
(Photocoupler Output)
d0: Not Used d1
3-06
Multi-Function Output2
(Relay Output)
d1: AC Drive Operational
d2: Max. Output Freq. Attained
d3: Zero Speed
d4: Over Torque
d5: Base-Block (B.B.)
d6: Low Voltage Detection
d7: AC Drive Operation Mode
d8: Fault Indication
d9: Desired Freq. Attained
d10: PLC Program Running
d11: PLC Program Step Complete
d12: PLC Program Complete
d13: PLC Program Operation Pause
d14: Terminal Count Value Attained
d15: Preliminary Count Value Attained
d16: Ready State Indicator
d17: FWD command indication
d18: REV command indication
d8