Chapter 7 Servo Parameters|ASDA-B Series
7-24 Revision February 2008, Doc. Name: 2006PDD23000009
Group 1: P1-xx Basic Parameters
P1 - 00
PTT External Pulse Input Type Communication Addr.: 0100H
Default: 2 Related Section:
Applicable Control Mode: P Section 3.3.3, Section 3.6.1,
Unit: N/A Section 6.2.1
Range: 0 ~ 142
Settings:
ASD-PU-01A ASD-PU-01B
P
P
:
0
-
0
2
1TT
Pulse type
Reserved
Logic type
Not used
Pulse type
0: AB phase pulse (4x)
1: CW + CCW pulse
2: Pulse + Direction
Other setting: Reversed
Input pulse interface Max. input pulse frequency
Line driver 500kpps
Open collector 200kpps
Logic type
0=Positive Logic 1=Negative Logic
Pulse Type
Forward Reverse Forward Reverse
AB phase pulse
CW + CCW pulse
Pulse + Direction