3.3 CMD (command code) and DATA (data character)
The format of data characters depends on the command code. The available command codes
are described as followed:
Command code: 03H, read N words. The maximum value of N is 10. For example,
reading parameters 01-01 and 01-02 from address 01H.
ASCII mode:
Command message: Response message: Error response message
STX ‘:’ STX ‘:’ STX ‘:’
ADR 1 ‘0’ ADR 1 ‘0’ ADR 1 ‘0’
ADR 0 ‘1’ ADR 0 ‘1’ ADR 0 ‘1’
CMD 1 ‘0’ CMD 1 ‘0’ CMD 1 ‘8’
CMD 0 ‘3’ CMD 0 ‘3’ CMD 0 ‘3’
Starting ‘0’ Number of ‘0’ Error code ‘0’
data ‘1’ data(Word) ‘4’ ‘2’
address ‘0’ Data ‘1’ LRC CHK 0 ‘6’
‘1’ of ‘7’ LRC CHK 1 ‘D’
Number ‘0’ 0101H ‘7’ END 1 CR
of ‘0’ ‘0’ END 0 LF
data ‘0’ Data ‘0’
(Word) ‘2’ of ‘8’
LRC CHK 1 ‘D’ 0102H ‘9’
LRC CHK 0 ‘7’ ‘8’
END 1 CR LRC CHK 1 ‘D’
END 0 LF LRC CHK 0 ‘1’
END 1 CR
END 0 LF